Vibration testing

ILT CODE: ILT-U-1872 Category:

Description: Level 1. Minimum frequency: 10 Hz.; o Frequency f1: 20 Hz Frequency f2: 1000 Hz; o Maximum frequency: 2000 Hz.; o RMS value: 3.35 g; o ASD form (flat between f1 and f2): 0.01 g2 / Hz; o Initial slope of 10 Hz: +6 dB / octave; Final slope between 1000 and 2000 Hz: -24 dB / octave; and Duration: 20 minutes Method: IEC 60068-2-64

ILT CODE: ILT-U-1872

Description: Level 1. Minimum frequency: 10 Hz.; o Frequency f1: 20 Hz Frequency f2: 1000 Hz; o Maximum frequency: 2000 Hz.; o RMS value: 3.35 g; o ASD form (flat between f1 and f2): 0.01 g2 / Hz; o Initial slope of 10 Hz: +6 dB / octave; Final slope between 1000 and 2000 Hz: -24 dB / octave; and Duration: 20 minutes

Method: IEC 60068-2-64

ILT – Interlaboratory Test
Scroll to Top